An Ex ia field I/O controller for a hazardous-area skid

Four intrinsically safe 4–20 mA channels, Ethernet and CAN on one 8-layer board, designed for Ex ia IIC T4 certification from the first schematic.

Client

Process-automation OEM (anonymised)

Timeline

16 weeks, concept to pilot

4

Ex ia channels on one board

8

layer stack, zero DRC errors

1st

pass EMC pre-scan

System overview

  1. Field sensors: 4× transmitters
  2. 4–20 mA to Zener barrier: Ex ia · fuse + 3 ZD
  3. IS → safe to Isolation: ISO7741 · transformer
  4. SPI to STM32H7: ADS124S08 · FreeRTOS
  5. Ethernet to SCADA: Modbus TCP

The challenge

The client’s existing controller sat in a separate safe-area cabinet with off-the-shelf barriers, adding wiring, panel space and cost to every skid. They needed the barrier, isolation and measurement on one board that a notified body could certify without a redesign.

What we built

  1. 01

    Segregated the layout with a milled slot and creepage-driven placement, with the isolation transformer and digital isolators straddling the boundary.

  2. 02

    Built each channel as a shunt-zener barrier: fuse, three zeners in parallel for the two-fault ia requirement, and an infallible current-limiting resistor.

  3. 03

    Routed an 8-layer stack with split GND / IS_GND and power planes, BGA dog-bone fan-out and stitching vias around every edge, all at 45°.

  4. 04

    Prepared the descriptive documents and entity-parameter calculations alongside the design, not after it.